Receive a weekly summary and discussion of the top papers of the week by leading researchers in the field.

In Eye (London, England) ; h5-index 41.0

OBJECTIVES : To determine the feasibility, validity and reliability of automatically extracting clinically meaningful eyelid measurements from consumer-grade videos of individuals with oculofacial disorders.

METHODS : A custom computer program was designed to automatically extract clinical measures from consumer-grade videos. This program was applied to publicly available videos of individuals with oculofacial disorders, and age-matched controls. The primary outcomes were margin reflex distance 1 (MRD1) and 2 (MRD2), blink lagophthalmos, and ocular surface area exposure. Test-retest reliability was evaluated using Bland-Altman analysis to compare the agreement in obtained measures between separate videos of the same individual taken within 48 h of each other.

RESULTS : MRD1 was reduced in individuals with ptosis versus controls (2.2 mm versus 3.4 mm, p < 0.001), and increased in individuals with facial nerve palsy (FNP) (3.9 mm, p = 0.049) and thyroid eye disease (TED) (4.1 mm; p = 0.038). Blink lagophthalmos was increased in individuals with FNP (3.7 mm); p < 0.001) and those with TED (0.1 mm, p = 0.003) versus controls (0.0 mm). Ocular surface exposure was reduced in individuals with ptosis compared with controls (12.2 mm2 versus 13.1 mm2; p < 0.001) and increased in TED (13.7 mm2; p 0.002). Bland-Altmann analysis demonstrated 95% limits of agreement for video-derived measures: median MRD1: -1.1 to 1.1 mm; median MRD2: -0.9 to 1.0 mm; blink lagophthalmos: -3.5 to 3.7 mm; and average ocular surface area exposure: -1.6 to 1.6 mm2.

CONCLUSIONS : The presented program is capable of taking consumer grade videos of patients with oculofacial disease and providing clinically meaningful and reliable eyelid measurements that show promising validity.

Schulz Christopher B, Clarke Holly, Makuloluwe Sarith, Thomas Peter B, Kang Swan

2023-Feb-01