Receive a weekly summary and discussion of the top papers of the week by leading researchers in the field.

In European radiology ; h5-index 62.0

OBJECTIVE : Low monoenergetic images obtained using noise-reduction techniques may reduce CT contrast media requirements. We aimed to investigate the effectiveness of low-contrast-dose CT using dual-energy CT and deep learning-based denoising (DLD) techniques in patients at high risk of hepatocellular carcinoma (HCC).

METHODS : We performed a prospective, randomized controlled noninferiority trial at a tertiary hospital between June 2019 and August 2020 (NCT04027556). Patients at high risk of HCC were randomly assigned (1:1) to the standard-contrast-dose group or low-contrast-dose group, which targeted a 40% reduction in contrast medium dose based on lean body weight. HCC conspicuity on arterial phase images was the primary endpoint with a noninferiority margin of 0.2. Images were independently assessed by three radiologists; model-based iterative reconstruction (MBIR) images of the standard-contrast-dose group and low monoenergetic (50-keV) DLD images of the low-contrast-dose group were compared using a generalized estimating equation.

RESULTS : Ninety participants (age 59 ± 10 years; 68 men) were analyzed. Compared with the standard-contrast-dose group (n = 47), 40% less contrast media was used in the low-contrast-dose group (n = 43) (107.0 ± 17.1 mL vs. 64.5 ± 11.3 mL, p < 0.001). In the arterial phase, HCC conspicuity on 50-keV DLD images in the low-contrast-dose group was noninferior to that of MBIR images in the standard-contrast-dose group (2.92 vs. 2.56; difference, 0.36; 95% confidence interval, -0.13 to ∞; p = 0.013).

CONCLUSIONS : The contrast dose in liver CT can be reduced by 40% without impairing HCC conspicuity when using 50-keV and DLD techniques.

KEY POINTS : • In the arterial phase, hepatocellular carcinoma conspicuity on 50-keV deep learning-based denoising images in the low-contrast-dose group was noninferior to that of model-based iterative reconstruction images in the standard-contrast-dose group. • HCC detection was comparable between 50-keV deep learning-based denoising images in the low-contrast-dose group and model-based iterative reconstruction images in the standard-contrast-dose group.

Bae Jae Seok, Lee Jeong Min, Kim Se Woo, Park Sungeun, Han Seungchul, Yoon Jeong Hee, Joo Ijin, Hong Hyunsook

2022-Dec-28

Body weight, Carcinoma, Hepatocellular, Contrast media, Deep learning, Tomography, X-ray computed