Receive a weekly summary and discussion of the top papers of the week by leading researchers in the field.

In EJNMMI physics

BACKGROUND : COVID-19 infection, especially in cases with pneumonia, is associated with a high rate of pulmonary embolism (PE). In patients with contraindications for CT pulmonary angiography (CTPA) or non-diagnostic CTPA, perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) is a diagnostic alternative. The goal of this study is to develop a radiomic diagnostic system to detect PE based only on the analysis of Q-SPECT/CT scans.

METHODS : This radiomic diagnostic system is based on a local analysis of Q-SPECT/CT volumes that includes both CT and Q-SPECT values for each volume point. We present a combined approach that uses radiomic features extracted from each scan as input into a fully connected classification neural network that optimizes a weighted cross-entropy loss trained to discriminate between three different types of image patterns (pixel sample level): healthy lungs (control group), PE and pneumonia. Four types of models using different configuration of parameters were tested.

RESULTS : The proposed radiomic diagnostic system was trained on 20 patients (4,927 sets of samples of three types of image patterns) and validated in a group of 39 patients (4,410 sets of samples of three types of image patterns). In the training group, COVID-19 infection corresponded to 45% of the cases and 51.28% in the test group. In the test group, the best model for determining different types of image patterns with PE presented a sensitivity, specificity, positive predictive value and negative predictive value of 75.1%, 98.2%, 88.9% and 95.4%, respectively. The best model for detecting pneumonia presented a sensitivity, specificity, positive predictive value and negative predictive value of 94.1%, 93.6%, 85.2% and 97.6%, respectively. The area under the curve (AUC) was 0.92 for PE and 0.91 for pneumonia. When the results obtained at the pixel sample level are aggregated into regions of interest, the sensitivity of the PE increases to 85%, and all metrics improve for pneumonia.

CONCLUSION : This radiomic diagnostic system was able to identify the different lung imaging patterns and is a first step toward a comprehensive intelligent radiomic system to optimize the diagnosis of PE by Q-SPECT/CT.

HIGHLIGHTS : Artificial intelligence applied to Q-SPECT/CT is a diagnostic option in patients with contraindications to CTPA or a non-diagnostic test in times of COVID-19.

Baeza Sonia, Gil Debora, Garcia-Olivé Ignasi, Salcedo-Pujantell Maite, Deportós Jordi, Sanchez Carles, Torres Guillermo, Moragas Gloria, Rosell Antoni

2022-Dec-05

COVID-19, CT, Neural networks, Pulmonary embolism, Radiomics, SPECT