In Medical physics ; h5-index 59.0
BACKGROUND : Many learning based low-dose (LD) computed tomography (CT) imaging methods require large paired full- and low-dose datasets for training, which are usually unavailable in clinic. Whereas models trained on simulated data often face the generalization problem on real clinical data.
PURPOSE : To develop an unsupervised learning technique to acquire clean CT projection from its adjacent LD projections.
METHODS : Given a sequential LD projection set, the method extracts out the middle projection as the target and treats the rest ones as the input. The model is trained with the mean absolute error with proposed inter-view gradient constraint term, which helps to suppress outliers and preserve edges in the denoised projection. The simulated Low-Dose CT Grand Challenge dataset and a real physical torso phantom dataset were employed for experiment. The peak signal to noise ratio (PSNR) and structural similarity index measure (SSIM) were calculated for quantitative evaluation.
RESULTS : In experiments with both the simulated and real datasets, visual comparisons reveal that the proposed method obtained images superior to unsupervised and supervised methods working in both image and projection domain. For numerical comparison, our method obtains larger SSIMs than other unsupervised methods at quarter and eighth dose levels. As for PSNR, our method obtains larger value at eighth dose whereas smaller value at quarter dose. The supervised models obtain better numerical results than all unsupervised models on simulated datasets.
CONCLUSION : The proposed method can reduce the noise in CT projections effectively, making it an attractive tool for practical LDCT preprocessing. This article is protected by copyright. All rights reserved.
Hong Zixuan, Zeng Dong, Tao Xi, Ma Jianhua
2022-Nov-22
computed tomography, gradient constraint, low-dose, projection denoising, unsupervised learning